Skip to content

SET_TRF

Download Flojoy Studio to try this app
The SET_TRF node sets the robot arm's reference frame. Inputs ------ ip_address: String The IP address of the robot arm. Params: rf_x : float The X coordinate of the reference plane. If not specified, the default value of 0.0 is used. rf_y : float The Y coordinate of the reference plane. If not specified, the default value of 0.0 is used. rf_z : float The Z coordinate of the reference plane. If not specified, the default value of 0.0 is used. rf_a : float The alpha angle of the reference plane. If not specified, the default value of 0.0 is used. rf_b : float The beta angle of the reference plane. If not specified, the default value of 0.0 is used. rf_g : float The gamma angle of the reference plane. If not specified, the default value of 0.0 is used. Returns: out : String The IP address of the robot arm.
Python Code
from flojoy import flojoy, String
from PYTHON.utils.mecademic_state.mecademic_state import query_for_handle
from PYTHON.utils.mecademic_state.mecademic_helpers import safe_robot_operation


@safe_robot_operation
@flojoy(deps={"mecademicpy": "1.4.0"})
def SET_TRF(
    ip_address: String,
    rf_x: float = 0.0,
    rf_y: float = 0.0,
    rf_z: float = 0.0,
    rf_a: float = 0.0,
    rf_b: float = 0.0,
    rf_g: float = 0.0,
) -> String:
    """
     The SET_TRF node sets the robot arm's reference frame.

    Inputs
    ------
    ip_address: String
        The IP address of the robot arm.

    Parameters
    ----------
    rf_x: float
        The X coordinate of the reference plane. If not specified, the default value of 0.0 is used.
    rf_y: float
        The Y coordinate of the reference plane. If not specified, the default value of 0.0 is used.
    rf_z: float
        The Z coordinate of the reference plane. If not specified, the default value of 0.0 is used.
    rf_a: float
        The alpha angle of the reference plane. If not specified, the default value of 0.0 is used.
    rf_b: float
        The beta angle of the reference plane. If not specified, the default value of 0.0 is used.
    rf_g: float
        The gamma angle of the reference plane. If not specified, the default value of 0.0 is used.

    Returns
    -------
    String
         The IP address of the robot arm.

    """
    robot = query_for_handle(ip_address)
    robot.SetTRF(rf_x, rf_y, rf_z, rf_a, rf_b, rf_g)
    return ip_address

Find this Flojoy Block on GitHub

Example App

Having problems with this example app? Join our Discord community and we will help you out!
React Flow mini map

In this example, the SET_TRF node sets the tool refernece frame for the robot arm.